Platform Switching Versus Conventional Technique: A Randomized Controlled Clinical Trial
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 34 , Issue 3
Supplement 2014

Pages s75-s79


Platform Switching Versus Conventional Technique: A Randomized Controlled Clinical Trial

Nicola De Angelis, DDS, DMSc/Marc L. Nevins, DMD, MMSc/Marcelo C. Camelo, DDS/Yoshihiro Ono, DDS/Michele Campailla, DDS/Stefano Benedicenti, DDS


PMID: 24956095
DOI: 10.11607/prd.2069

In this controlled prospective study, 53 patients treated at four study centers were randomly assigned to receive either (test) implants with platform switching built into their design or similar nonplatform-switched controls (same manufacturer, surface treatment, etc) for treatment of single and multiple edentulous sites in all four quadrants. Radiographs taken at the time of implant placement, definitive restoration delivery, and 1-year follow-up found significantly less crestal bone loss around the test implants (0.25 mm) compared to the controls (0.65 mm). Notably, bone loss around the control implants had declined by the 1-year follow-up point. (Int J Periodontics Restorative Dent 2014;34(suppl):s75–s79. doi: 10.11607/prd.2147)


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 